Cleaning Issues with electrogalvanized steel
Organic coated job (0.8 mm CRS Electrogalvanized Zinc coated sheet) not proper oil removed by degreasing stage, Suppose Use for Alkaline chemicals e.g Ridolene 53S Caustic base 0.2 % & Ridosol
550B By Henkel.
Problems.
Brown Ring on Pressing Portion.
Etching On Bending Portion.
Oil Patches.
plating shop employees - Pune
November 29, 2009