Sound technical content, curated with aloha by
Ted Mooney, P.E. RET
Pine Beach, NJ
The authoritative public forum
for Metal Finishing since 1989
-----
Nodular extra chromium deposit at inside of dia 40mm rings
I am venketrajan working in LMW, coimbatore as a technical staff. We are doing hard chromium plating on high carbon low alloy steels in plenty. We are facing nodular extra chromium deposit at inside of rings especially. We are using inner anodes (Lead/Tin) of dia. 16 mm. Also we are inspecting 100% after plating with 10X magnification.
Please suggest the possible cause and remedy for overcoming this issue.
Plating shop employee - Coimbatore, Tamilnadu, India
December 20, 2008
December 22, 2008
Hi, Venketrajan. You probably still have too much current density at this edge. Although I can't really picture the details of your installation without more hints, I think you may need "thieves" to handle the current at these edges.
Regards,
Ted Mooney, P.E.
Striving to live Aloha
finishing.com - Pine Beach, New Jersey
Q, A, or Comment on THIS thread -or- Start a NEW Thread