Curated with aloha by
Ted Mooney, P.E. RET

The authoritative public forum
for Metal Finishing 1989-2025

-----
What is E512 per MIL-F-14072

Q. What is E512 per MIL-DTL-14072 [on DLA]?
Larry Davilaqa manager - Gardena, California
2007

"Chromating - Anodizing - Hardcoating"
by Robert Probert
Also available in Spanish
You'll love this book. Finishing.com has sold almost a thousand copies without a single return request :-)
A. See MIL-DTL-14072E Finishes for Ground Based Electronic Equipment, page 44:
TABLE IV. Finishes or processes other than painting or plating (E) - continued.
For Use On: Aluminum alloys when Low Resistance Electrical Contacts are required; service temperatures not to exceed 60 °C
Type Exposure: II
Finish Number: E512
Finish Process: 1) Preconditioning not required.
2) Passivate with chemical film per MIL-DTL-5541
[on DLA], Class 3.
- Goleta, California

Rest in peace, Ken. Thank you for your hard work which the finishing world, and we at finishing.com, continue to benefit from.