MIL STD 105E
2006
Hello,
for the application of MIL-STD-105E procedure,is it possible o modify the listed sample number? Because I have limitation of human resource if I have to follow the procedure. For example, N=4500 AQL=0.1 and level = I then I'll get sample size 125 pieces with certain N and C value. Is it possible to reduce the sample number?
Thanks for your help.
electronics (lamps) mfgr. - Surabaya, Indonesia
See Paragraph 4.7.3 for switching from normal to reduced level of inspection. Basically, it's allowed if good results were obtained for the previous 10 lots inspected. Possibly, negotiable with your customer.
Also, get
MIL-HDBK-53/1A, "GUIDE FOR ATTRIBUTE LOT SAMPLING INSPECTION AND MIL-STD-105."
- Goleta, California
Finishing.com honored Ken for his countless carefully researched responses. He passed away May 14, 2015.
Rest in peace, Ken. Thank you for your hard work which the finishing world, and we at finishing.com, continue to benefit from.