Curated with aloha by
Ted Mooney, P.E. RET

The authoritative public forum
for Metal Finishing 1989-2025

-----
Lead-free, Zinc ED plating
I have a few automotive accessory , the raw material is DIN EN 10149-2 S460MC,
GALVANNEALED structural steel. The finishing process requirement =
Lead-free , Zinc ED plating, it must withstand Salt Spray Test : ASTM B117 -2003,
72 Hrs without base metal corrosion .
I want to know is there any Lead-free , Zinc ED plating process available within Singapore & Malaysia & What is the description for Lead-free , Zinc ED plating .
Thank you & have a nice day .
OEM , Procurement Staff. - Singapore
2006
I would read this as " Lead Free CED Coating to be applied over galvanised zinc coated steel". The corrosion coating requirement of 72 hours SST could easily be achieved.

Khozem Vahaanwala
Saify Ind

Bengaluru, Karnataka, India

2006