How to read IPC-6012b microsection with plated up copper
2006
I know this sounds very un-informed but what is reality. I would like some advice on a question that's been bothering me.
When you have 1 oz copper inner to start and you plate up to 2 oz.
(add 1 oz) Do you follow the IPC table 3.7, for 2 oz and expect that the plating thickness should be .002193?
Or, if I follow the table for 1 oz plus 1 oz added minus the variable process, I get.000980 x 2=.001960? Which is correct?
QAM, printed circuit board mfg. - Seattle, Washington