How to read IPC-6012b microsection with plated up copper





2006

I know this sounds very un-informed but what is reality. I would like some advice on a question that's been bothering me.
When you have 1 oz copper inner to start and you plate up to 2 oz. (add 1 oz) Do you follow the IPC table 3.7, for 2 oz and expect that the plating thickness should be .002193?

Or, if I follow the table for 1 oz plus 1 oz added minus the variable process, I get.000980 x 2=.001960? Which is correct?

Terrie Black
QAM, printed circuit board mfg. - Seattle, Washington




(No "dead threads" here! If this page isn't currently on the Hotline your Q, A, or Comment will restore it)

Q, A, or Comment on THIS thread -or- Start a NEW Thread

Disclaimer: It's not possible to fully diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations might be harmful.