Sound technical content, curated with aloha by
Ted Mooney, P.E. RET
Pine Beach, NJ
The authoritative public forum
for Metal Finishing 1989-2024
-----
Passivation to meet AMSQQP35 TYPE 2/ TYPE 8
Is there any other way to passivate stainless to meet with military QQ-P-35C (canceled) [link is to free spec at Defense Logistics Agency, dla.mil] TYPE 2/ TYPE 8 without the use of Nitric Acid?
Dustin Colinaelectropolishing - Clearwater, Florida
2005
adv.
We have developed passivation technology based on low concentration of phosphoric acid. It is environmentally friendly and can be applied for food industry also. Contact us for details.
Anna Berkovich
Russamer Lab
Pittsburgh, Pennsylvania
2005
Dustin, you can passivate without using nitric acid, as Anna says, and as other folks who use citric acid will tell you. Yet AMSQQP35 [canceled] Type 2 or Type 8 both require nitric acid. If you're locked into using that specification, you are locked into using nitric acid based formulations.
Lee Gearhart
metallurgist - E. Aurora, New York
2005
this text gets replaced with bannerText
Q, A, or Comment on THIS thread -or- Start a NEW Thread