ENP coating on ball valves




Maximum temperature limitation of the ENP coating on Ball valves.We have services with Operating temperature about 160 deg.C and Design temperature of 180 deg.C.

DHAYANAND
- SHARJAH, UAE
2005



Hi DHAYANAND,

All Electroless Nickel Coating begin to melt at 880 °C.

Sridhar Bushigampala
- Toronto, ON, Canada
2005



2005

Unless there is a very large amount of H2S present, EN should be suitable for ball valves in oil & gas applications to at least 200 °C. NACE Publication 6A287 gives an overview of corrosion limitations in such environments.

Ron Duncan
Ron Duncan [deceased]
- LaVergne, Tennessee
It is our sad duty to note Ron's passing on Dec. 15, 2006. A brief obituary opens Episode 13 of our Podcast.





(No "dead threads" here! If this page isn't currently on the Hotline your Q, A, or Comment will restore it)

Q, A, or Comment on THIS thread -or- Start a NEW Thread

Disclaimer: It's not possible to fully diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations might be harmful.

If you are seeking a product or service related to metal finishing, please check these Directories:

Finishing
Jobshops
Capital
Equipment
Chemicals &
Consumables
Consult'g,
& Software


About/Contact  -  Privacy Policy  -  ©1995-2024 finishing.com, Pine Beach, New Jersey, USA  -  about "affil links"