Req'd frequency of Mil-C-5541 testing of brush-on solution
Per MIL-C-5541, using a brush-on solution, is it required to be tested "weekly" like other solutions are to verify Process Solution Control?
Thanks,
Michael Stallingsaircraft - Palmdale, California, USA
2004
Yes, it is required to analyze the solution WEEKLY, if the solution is being used regularly, if the usage is intermittent, and the intervals are more than a week, than at start of each use.
Mussadiq Hussain- Canyon Country, California, USA