Hydrofluoric Acid Contamination Treatment
We are having 2 to 5% of HF contamination in our effluent water, which we want to remove/convert and reuse the same.
Welcome all your suggestions
- PONDICHERRY, Pondicherry - Union Territory, India
2003
Your question is a bit vague, Mr. Annadurai. 100 gallons per week or per second? How did it get the hydrofluoric acid in it, what else is in it, and in what way do you want to re-use it? Thanks!
Ted Mooney, P.E.
Striving to live Aloha
finishing.com - Pine Beach, New Jersey
2003
2003
Mr Annadurai,
The solution to your problem is to find a local company that installs Reverse Osmosis equipment. Tamil Nadu State Pollution Control Board has a consultancy advisory too in Chennai.
Asif Nurie [deceased]
- New Delhi, India
With deep regret we sadly advise that Asif passed away on Jan 24, 2016