BURNING IN HIGH CD ON LOW JUICE
Help required on dull cad solution. We run a dull cad @ 15g/l Cd metal, 7g/l NaOH & 60g/l NaCN the carbonate is about 50 g/l.We have problems with high cd burning plating at very low juice Helpppp!
Greg Yates- Manchester, U.K.
2003
First of two simultaneous responses --
NaOH should be approx. 110 g/l. It can make the whole difference!
Sara Michaeli
Tel-Aviv-Yafo, Israel
2003
Second of two simultaneous responses --
Your concentrations sound on the low end, but acceptable. Have you run some hull cell panels? This would not only quantify your concept of "low juice" and put some real numbers on it, but would also eliminate several possible trouble spots like defective rectifiers.
Ted Mooney, P.E.
Striving to live Aloha
finishing.com - Pine Beach, New Jersey
2003