Letter 4036

Conductive finish for colled rolled steel. 

-

I am looking for a finish I can apply to colled rolled steel that is conductive. I have EMI issues on a product and and am currenly using clear zinc on my CRS chassis, but the coating is not conductive enough. Anys suggestions? Someone suggested "alkaline zinc", but am not familiar with it.

David Rapp - somnus medical - sunnyvale, ca


-

Zinc can be electroplated from an acid bath, a cyanide bath, or an alkaline non-cyanide bath. "Someone" was suggesting a bath you could use, and perhaps describing the relative advantages of it, but I am not aware of any significant difference in conductivity of the plated surface that might result from using one zinc bath versus another.

The clear chromate you are using will give you a lower contact resistance than would a yellow chromate.

Please also see letters #485, #2287, and #3617.


Ted Mooney, P.E. 
finishing.com
Brick, New Jersey


Dear Reader, please --

Answer or follow-up on this subject
 
Post a new question or inquiry on a different subject
 
This is a monitored forum. If you spot broken links or obsolete info, please advise!

 